Penentuan Dosis Efektif Pada Pemeriksaan CT Scan Kepala Anak Dengan Software Indose CT

Elshaday S.B Siregar, Ngurah Sutapa, I Wayan Balik Sudarsana

Abstract


CT Scan for head data for children have been processed by using a software name IndoseCT. CT Scan usually use for diagnose part of human body, but CT Scan for head is the most. Data processing was carried out with the IndoseCT software to obtain effective dose values. The highest effective dose value with contrast and non contrast received by 1 until 5 years old patients. Examination with contrast has an effective dose value of 1.29 mSv and for non contrast examination has an effective dose value od 1.16 mSv, meanwhile the lowest effective dose for examination with contrast received by 0 until 1 years old patients with value of 0.94 mSv and for non contrast examination of 0.9 mSv received by 16 until 18 years old patient.

Keywords


Head CT Scan, Effective Dose, Software, Indose CT

Full Text:

PDF

References


Akhadi, Mukhlis, 2000, Dasar-Dasar Proteksi Radisi, PT. Rineka Cipta, Jakarta.

Anam, dkk., 2016, IndoseCT Software for Calculating and Managing Radiation Dose of Computed Tomography for an Individual Patient, Indonesia.

Kofler, James.M, etc., 2010, Estimating Effective Dose for CT Using Dose-Length Product Compared With Using Organ Doses : Consequences of Adopting International Comission on Radilogical Protection Publication 103 or Dual-Energy Scanning, Research, American Journal of Radiology 2010.194.881-889. America.

Ramadhani, Putri, 2006, Elektronika Kedokteran, Jurusan Elektro, Fakultas Teknik, Universitas Hasanuddin, Makassar.

Silvia, dkk., 2013, Estimasi Nilai CTDI dan Dosis Efektif Pasien Bagian Head, Thorax dan Abdomen Hasil Pemeriksaan CT Scan Merek Philips Briliance 6, Jurnal Fisika Unand, Vol.2, No.2, Jurusan Fisika, Universitas Andalas, Padang.

Sirait, Pitta, 2017, Pengaruh Field of View (FOW) dan Slice Thickness Terhadap Dosis Radiasi pada CT Scan, Skripsi, Departemen Fisika, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Sumatera Utara, Medan.

Soediatmoko,Elia, 2011, Estimasi Dosis Radiasi pada Pemeriksaan CT Scan Kepala, Skripsi, Program Studi Fisika, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Indonesia, Jakarta.

Syahputra, Muhammad. J, 2017, Penngaruh Radiasi dengan Menggunakan Protokol Low Dose KV, mA dan Pitch pada CT Scan Pelvis, Skripsi, Departemen Fisika, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Sumatera Utara, Medan.

Untari, Ida, Kesehatan Otak Modal Dasar Hasilkan SDM Handal, 2012, Profesi, Akademi Keperawatan PKU Muhammadiyah Surakarta, Solo.


Article Metrics

Abstract view : 0 times
PDF - 0 times

Refbacks

  • There are currently no refbacks.


Copyright (c) 2019 Kappa Journal

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

Creative Commons License
Kappa Journal by http://e-journal.hamzanwadi.ac.id/index.php/kpj is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.

View my stats