The Effect of Focus Film Distance Variation on Patient Absorbed Dose in Thorax Examination with Roentgen Machine in Radiology Installation of Sanjiwani Hospital Gianyar

Authors

  • I Nyoman Yosua Universitas Udayana
  • Gusti Ngurah Sutapa Universitas Udayana
  • I Ketut Putra Universitas Udayana
  • Ida Bagus Suryatika Universitas Udayana
  • Hery Suyanto Universitas Udayana
  • Ida Bagus Alit Paramarta Universitas Udayana

DOI:

https://doi.org/10.29408/kpj.v8i3.28113

Keywords:

Focus Film Distance, absorbed dose, X-ray machine, thorax examination

Abstract

A study has been conducted on the effect of Focus Film Distance (FFD) variation on patient absorbed dose during thorax examination at the Radiology Installation of Sanjiwani Hospital, Gianyar. This study aims to determine the effect of FFD variation and the suitability of the radiation dose received by patients whether it is still within the limits of BAPETEN's decision. The X-ray machine used was Siemens Luminos Fusion Roentgen with the FFD variation method given a distance of 110 cm, 130 cm, and 150 cm in 30 patients. Dose measurements were carried out based on radiation exposure and analyzed according to BAPETEN standards. The results showed that the greater the FFD value, the smaller the absorbed dose received by patients. The highest absorbed dose obtained for FFD 110 cm was 0.3867 mGy, 130 cm was 0.2769 mGy, and 150 cm was 0.2079 mGy below the maximum limit of 0.4 mGy set by BAPETEN, so it is safe for patients. Statistical analysis of one-way t-test showed significant results, with thitung < ttabel. This indicates that FFD variation affects the absorbed dose, and all doses remain within safe limits. Thus, thorax examination at RSUD Sanjiwani Gianyar has met the established safety standards.

References

BAPETEN. (2021). Peraturan Kepala Badan Pengawas Tenaga Nuklir Nomor 12111/K/V/2021 Tentang Penetapan Nilai Tingkat Panduan Diagnostik Indonesia (Indonesian Diagnostic Reverence Level) Untuk Modalitas Sinar-X CT Scan dan Radiografi Umum. Jakarta

Firdaus, A. R., Alwiyah, A. U., & Sudarti. (2024). Analisis Strategi Proteksi Radiasi pada Tenaga Kerja di Instalasi Radiologi Rumah Sakit. Eduproxima: Jurnal Ilmiah Pendidikan IPA, 6(1), 44-51. Retrieved from http://jurnal.stkippgritulungagung.ac.id/index.php/eduproxima

Fuadi, N., Jusli, N., & Harmini. (2022). Pemantauan Dosis Perorangan Menggunakan Thermoluminescence Dosimeter (TLD) di Wilaya Papua dan Papua Barat Tahun 2020-2021. Jurnal Sains Fisika, 2(1), 63-74. Retrieved from https://journal.uin-alauddin.ac.id/index.php/sainfis/article/view/27666

Hadinata, I. M., & Sutapa, I. G. (2019). Pengaruh Usia Terhadap Besarnya Dosis Serap Radiasi Sinar-X yang Diterima Pasien Pemeriksaan Toraks. Kappa Journal, 3(2), 142-147. doi:https://doi.org/10.29408/kpj.v3i2.1620

Medropa, S. G., & Nababan, S. (2018). Analisis Pengaruh Focus Film Distance Pada Pesawat Rontgen General Purpose. Jurnal Mutiara Elektromedik, 2(1), 11-15. Retrieved from https://e-journal.sari-mutiara.ac.id/index.php/Elektromedik/article/view/3217

Meredith, W. J., & Massey, J. N. (1977). Fundamental Physics of Radiology 3 Edition. Chicago: Elsevier Science.

Romarti, C., Pebralia, J., & Anggraini, R. M. (2023). Efektivitas Dosis Paparan Radiasi dari Pesawat Panoramik di Instalasi Radiologi Rumah Sakit Umum Daerah Raden Mattaher Jambi. Journal Online of Physics, 9(1), 90-97. Retrieved from https://online-journal.unja.ac.id/jop/article/download/27310/16637/84410

Santoso, S. (2018). Menguasai SPSS Versi 25. Jakarta: Elex Media Komputindo.

Souisa, F., Ratnawati, & Sudarsana, B. (2014). Pengaruh perubahan jarak obyek ke film terhadap pembesaran obyek pada pemanfaatan oesawat sinar-X type CGR. Buletin Fisika, 15(2), 15-21. Retrieved from https://ojs.unud.ac.id/index.php/buletinfisika/article/view/30804

Sugiyono. (2019). Statistika Untuk Penelitian. Bandung: Alfabeta.

Downloads

Published

2024-12-26

Issue

Section

Articles