Pengaruh Focus Film Distance (FFD) terhadap Nilai Uji Kolimasi pada Kolimator Pesawat Sinar-X Stasioner untuk Pemeriksaan Pasien
DOI:
https://doi.org/10.29408/kpj.v9i1.28903Keywords:
Collimation test, focus film distance, FFD, illumination test, collimation field discrepancy with X-ray beam, X-ray beam perpendicularityAbstract
A study has been conducted on the effect of Focus Film Distance (FFD) on the collimation test values of stationary X-ray unit collimators for patient examinations. This research aims to determine the extent to which FFD affects collimation test values. The FFD variations used were 90 cm, 95 cm, 100 cm, 105 cm, 110 cm, 115 cm, and 120 cm. There are three tests in the collimation test: illumination test, collimation field discrepancy with X-ray beam, and X-ray beam perpendicularity. The illumination test was conducted using a lux meter, which was then averaged per FFD. The resulting illumination values corresponding to the FFD variations were 425.25 lux, 381.55 lux, 343.90 lux, 311.80 lux, 283.50 lux, 259.45 lux, and 238.20 lux. These results conform to the inverse square law. For the collimation field discrepancy values |dX| and |dY|, corresponding to the FFD variations, the values were 0.68 and 0.62; 0.32 and 0.34; 0.02 and 0.02; 0.10 and 0.08; 0.18 and 0.20; 0.34 and 0.32; 0.48 and 0.50, respectively. The X-ray beam perpendicularity value remained constant for all FFD variations at 1.03º. The values obtained from the three tests comply with the Indonesian Ministry of Health Regulation No. 1250/MENKES/SK/XII/2009 concerning Quality Control Guidelines for Radiodiagnostic Equipment.
References
A’yun, Q. R., 2019, Pengujian Kolimator Pesawat Sinar-X Toshiba DRX-1603B di Instalasi Radiologi Rumah Sakit Roemani Muhammadiyah Semarang. Karya Tulis Ilmiah. Program Studi Diploma III Teknik Radiodiagnostik dan Radioterapi Politeknik Kesehatan Kemenkes Semarang.
BAPETEN, 2009, Pedoman Penanggulangan Kedaruratan Radiologi untuk Pelaksana Tanggap Darurat. Badan Pengawas Tenga Nuklir, Jakarta.
BAPETEN, 2011, Peraturan Kepala Badan Pengawas Tenaga Nuklir Nomor 8 Tahun 2011 tentang Keselamatan Radiasi Dalam Penggunaan Pesawat Sinar X Radiologi Diagnostik dan Intervensional, Badan Pengawas Tenaga Nuklir, Jakarta.
BAPETEN. 2014. Peraturan Badan Pengawas Tenaga Nuklir Republik Indonesia Nomor 15 Tahun 2014 tentang Keselamatan Radiasi dalam Produksi Pesawat Sinar-X Radiologi Diagnostik dan Intervensional. Dokumen Teknis, Badan Pengawas Tenaga Nuklir, Jakarta.
BAPETEN, 2019, Buku Pedoman Layanan Perizinan Pesawat Sinar-X Radiologi Diagnostik dan Intervensional. Dokumen Teknis, Badan Pengawas Tenaga Nuklir: Jakarta.
Dabukke, H., 2018, Pengujian Iluminasi, Kolimasi, Ketegaklurusan dan Kualitas Berkas Pesawat Sinar-X Radiografi Umum dengan Radiografi Mobile. Tesis. Program Studi Magister (S2) Fisika Fakultas Matematika dan Ilmu Pengetahuan Alam. Universitas Sumatera Utara
Febriani, Siti D. A., 2013, Optimalisasi Dosis Serap dan Kontras Radiograf dengan Permodelan Phantom Akrilik. Skripsi. Jurusan Fisika Fakultas Matematika dan Ilmu Pengetahuan Alam. Universitas Jember.
Ferryadi, M., 2017, Penentuan Ketepatan Titik Pusat Berkas Sinar dari Sudut berkas pada Pesawat General X-ray sebagai Parameter Kualitas Kontrol. Skripsi. Jurusan Fisika Fakultas Matematika dan Ilmu Penegetahuan Alam. Universitas Sumatra Utara.
Haryani, L. Wahyu, 2021, Analisis Uji Kolimator Pesawat Sinar-X dengan membandingkan Akurasi antara Beam Alignment Test Tool Tiruan dan Gammex 162A Beam Alignment Test Tool di RSUD Dr. Moewardi Surakarta. Skripsi. Jurusan Fisika Fakultas Matematika dan Ilmu Penegetahuan Alam. Universitas Sebelas Maret.
Husain, W. 2021. Analisis Pengaruh Tegangan Tabung dan Arus terhadap Daya Serap Radiasi dan Laju Dosis Radiasi pada Bahan Serat Ijuk dan Timbal (II) Oksida sebagai Perisai Sinar-X. Skripsi Departemen Fisika Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Hasanuddin. Makassar.
KEPEMENKES, 2009, Keputusan Menteri Kesehatan No.1250/MENKES/SK/XII/2009 tentang Pedoman Kendali Mutu (Quality Control) Peralatan Radiodiagnostik.
Khan, M.F., 2014, The Physics of Radiation Therapy, The 4th edition, Lippincott Wiliams and Wilkins, New York.
Marcellino, Nathaniel, 2023, Uji Kesesuaian Kolimasi Pesawat Fluoroskopi di Instalasi Radiologi RSD Mangusada Badung. Prosiding Seminar Keselamatan Nuklir BAPETEN. Universitas Udayana.
Mayani, A. N, dan Muhflihatun, 2017, Pengaruh Variasi Focus Film Distance (FFD) terhadap Hasil Presisi Pengukuran Cardiothoracic Ratio (CTR). Prosiding Pertemuan dan Presentasi Ilmiah Penelitian Dasar Ilmu Pengetahuan dan Teknologi Nuklir. Hal 59-64.
Podgorsak, E. B., 2005. Radiation Oncology Physics: A Handbook For Teachers And Students, International Atomic Energy Agency. Vienna. IAEA. Austria.
Priyono, S., Anam, C., Budi, Wahyu S., 2020. Pengaruh Rasio Grid terhadap Kualitas Radiograf Fantom Kepala. Jurnal Berkala Fisika. Vol 23 (1): 10 -16.
Sapitri, D. R., Sri Mulyasih, Utami A. P., 2017, Pengujian Kolimator pada Pesawat SinarX Merk Hitachi di Instalasi Radiologi Rumah Sakit Dr. Adyatma MPH Semarang. Jurnal Ilmiah Radiologi. Vol 5 (2).
Sari, Ayu W. 2018. Pengaruh Faktor Eksposidengan Ketebalan Objek pada Pemeriksaan Foto Thorax Terhadap Gambaran Radiografi. Journal of Healt. Vol 5 (1): 17-21
Satwika, L.G Puja, dan Ratini, N.N., 2019, Uji Kesesuaian Iluminasi Lampu Kolimator pada Pesawat Sinar-X Konvensional di RSUP Sanglah Denpasar. Prosiding SEMINAR NASIONAL SAINSTEK. Hal 18-27.
Satwiko, Prasasto, 2004, Fisika Bangunan 1 Edisi 1, Andi: Yogyakarta.
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Kappa Journal

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Semua tulisan pada jurnal ini menjadi tanggungjawab penuh penulis. Jurnal Kappa memberikan akses terbuka terhadap siapapun agar informasi dan temuan pada artikel tersebut bermanfaat bagi semua orang. Jurnal Kappa dapat diakses dan diunduh secara gratis, tanpa dipungut biaya, sesuai dengan lisensi creative commons yang digunakan