Uji Kesesuaian Alat Proteksi Radiasi Berdasarkan Nilai Exposure Index (EI) di Rumah Sakit Bali Mandara
DOI:
https://doi.org/10.29408/kpj.v10i1.31760Keywords:
X-ray, CR system, EI, APD Radiation ProtectionAbstract
A study has been conducted on the suitability test of radiation protection equipment based on the Exposure Index (EI) at Bali Mandara Hospital. The data used in this study are primary data obtained by conducting X-ray irradiation on PPE, namely Apron, Gonad Shield, thyroid Shield, gloves, and glasses using an X-ray machine. Then the irradiation results are processed using a CR system machine to obtain EI values using variations in tube voltage of 80 Kv, 100 Kv, 130 Kv, and a time current of 18 mAs. From the results of the analysis that has been carried out, the average EI value was obtained with a tube voltage of 80 kV for Apron 1004.60 ± 1.72, gonad shield 1302.80 ± 1.94, Thyroid shield 1444.60 ± 1.63, glasses 1375.40 ± 1.72, gloves 1478.60 ± 0.93, for a tube voltage of 100 kV the EI value for the apron was 1511.20 ± 1.24, gonad shield 1697.80 ± 1.65, thyroid shield 1810.60 ± 1.57, glasses 1598.60 ± 1.33, gloves 1819.40 ± 0.75, for a tube voltage of 130 kV 1831.00±1.41, gonad shield 2090.60±1.21, thyroid shield 2129.00±2.00, glasses 2980.20±1.07, gloves 2114.00±1.41. The EI value obtained using 80 kV tube voltage is still within the limits set by PERKA BAPETEN No.8 of 2011, namely 1300-1800
References
Ancila C., dan Hidayanto E., 2016, Analisis Dosis Paparan Radiasi pada Instalasi Radiologi Dental Panoramik, Youngster Physics Journal, Vol.5 (4): 441-450.
Aryawijayanti R., dan Susilom Sutikno, 2015, Analisis Dampak Radiasi Sinar-X pada Mencit Melalui Pemetaan Dosis Radiasi di Laboratorium Fisika Medik, Jurnal MIPA, Vol.38(1) : 25-30.
Baker, M, 2012, Investigation into Factors Influencing Fuji S-Value Using an Extremity Phantom, Journal of Medical Imaging and Radiation Sciences, Vol.43(1): 34–37.
Bontrager, K.L. dan Lampignano, J.P, 2010, Textbook of Radiographic Positioning and Related Anatom, 7th Edition, Saint Louis: Mosby Elsevier.
Dabukke, H, 2015, “Pengaruh Faktor Ekspose Terhadap Kontras Resolusi CT Scan”, Skripsi, Departemen Fisika, Jurusan Fisika Medik, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Sumatra Utara, Medan.
Dabukke, H, 2018, “Pengujian Iluminasi, Kolimasi, Ketegaklurusan dan Kualitas Berkas Pesawat Sinar-X Radiografi Umum dengan Radiografi Mobile”, Tesis, Universitas Sumatetra Utara, Medan.
Gibson, D.J. dan Davidson, R.A, 2012, Exposure Creep in Computed Radiography: A Longitudinal Study, Academic Radiology, Vol.19(4): 458-462.
Hidayah, R., Hidayanto, E., dan Arifin, Z, 2015, Analisa Pengaruh pH terhadap Perubahan Nilai Densitas Optik (Optical Density) pada Film dengan Variasi Jenis Developer, Youngster Physics Journal, Vol.4(1): 73-78.
Hiswara E., 2015, Buku Pintar Proteksi Keselamatan Radiasi di Rumah Sakit, Jakarta: BATAN Press
Jannah, N., Armynah, B., & Abdullah, B. (2019). Analisis Kurva Karakteristik Image Plate Computed Radiography (CR) Sebagai Indikator Sensitifitas Terhadap Sinar-X Analysis of the Characteristic Curve of the Image Plate Computed Radiography (CR) as an Indicator of X-Ray Sensitivity. Physio, 7(4265–4275), 7–15.
Seibert, J. A. dan Morin, R. L, 2011, The standardized exposure index for digital radiography: an opportunity for optimization of radiation dose to the pediatric population, Pediatric radiology, Vol.41: 573-581.
Kartikasari, Y., Fathoni, M. A. N., dan Indrati, R., 2018, Uji Fungsi Alat Pelindung Radiasi (Lead Apron) di Instalasi Radiologi Rumah Sakit, Seminar Nasional Sdm Teknologi Nuklir, Yogyakarta, Issn 1978-0176.
Lampignano, J., & Kendrick, L. E. (2017). Bontrager’s Textbook of Radiographic Positioning and Related Anatomy-E-Book: Bontrager’s Textbook of Radiographic Positioning and Related Anatomy-E-Book. Elsevier Health Sciences.
Mustofa, A. A., Hadziqoh, N., dan Lasiyah, N, 2024, Analisis Tingkat Keselamatan Peralatan Proteksi Radiasi Terhadap Radiographer Pada Rumah Sakit B Pekanbaru, Interdisciplinary Journal of MedTech and EcoEngineering, Vol.1(1): 41-47.
Percuoco, R, 2014, Chapter 1 - Plain Radiograpic Imaging, Clinical Imaging 3rd Edition, Saint Louis: Mosby, 12-14.
Permenkes, 2020, Peraturan Menteri Kesehatan Republik Indonesia Nomor 24 Tahun 2020 Tentang Pelayanan Radiologi Klinik, Jakarta: Permenkes.
Romans, L.E, 2011, Computed Tomography for Technologists: A Comprehensive Text, New Yok: LWW.
Romli M., 2016, Penilaian resiko Kesehatan Terhadap Radiasi Pengion, Buletin Limbah, Vol.13(2) : 27-33.
Seeram, E, 2014, The New Exposure Indicator for Digital Radiography, Journal of Medical Imaging and Radiation Sciences, Vol.45(2): 144–158.
Seeram, E. dan Brennan, P. C, 2017, Radiation protection in diagnostic X- Ray imaging, Jones & Bartlett Learning.
Septiyanti, I., Khalif M.A., dan Anwar, E.D., 2020, Analisis Dosis Paparan Radiasi Pada General X-ray II di Instalasi Radiologi Rumah Sakit Muhammadiyah Semarang, Jurnal Imajing Diagnostik, Vol.6 : 96-102.
Shekti, S. A., 2022, Perbandingan Kualitas Citra Pada Radiografi Abdomen Dengan Menggunakan Moving Grid, Stationary Grid Dan NonGrid, Skripsi.
Shepard, S. J., Wang, J., Flynn, M., Gingold, E., Goldman, L., Krugh, K., Leong, D. L., Mah, E., Ogden, K., Peck, D., Samei, E., Wang, J., dan Willis, C. E, 2009, An exposure indicator for digital radiography: AAPM Task Group 116 (executive summary). Medical physics, Vol.36(7): 2898–2914
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Kappa Journal

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Semua tulisan pada jurnal ini menjadi tanggungjawab penuh penulis. Jurnal Kappa memberikan akses terbuka terhadap siapapun agar informasi dan temuan pada artikel tersebut bermanfaat bagi semua orang. Jurnal Kappa dapat diakses dan diunduh secara gratis, tanpa dipungut biaya, sesuai dengan lisensi creative commons yang digunakan