Estimasi Dosis Radiasi Sinar-X Terhadap Efek Herediter Pada Radiografi Konvensional

Authors

  • Sylvia Ariska Susanti Jurusan Fisika, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Udayana
  • Gusti Ngurah Sutapa Jurusan Fisika, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Udayana
  • Maghfirottul Iffah Jurusan Fisika, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Udayana

DOI:

https://doi.org/10.29408/kpj.v6i2.6467

Keywords:

Absorbed dose, hereditary effects, organs, cells, voltage

Abstract

A study has been carried out on the estimation of X-ray dose on hereditary effects on conventional radiography. The research was conducted at the Bali Academy of Radiodiagnostic and Radiotherapy Engineering using a Raysafe X-Ray Multimeter. Secondary data was obtained in the form of results of checking the output voltage (kV), exposure time (ms) and exposure (mGy). The data obtained are then grouped according to the voltage used. The data is used to calculate the Entrance Surface Dose (ESD) value, which is then used to find the value of the Hereditary effect on the examination of each organ. In this study, the lowest ESD value was found at the use of a voltage of 40 kV, namely 0.3737 mGy, while the highest ESD value was at the use of a voltage of 80 kV, which was 0.7328 mGy. Based on the calculation of hereditary effects for generation I has the highest probability compared to generation II, this is very dependent on the ability of cells after exposure to radiation. Cells in general can make natural repairs. The longer the time after exposure to radiation, the more cells have the opportunity to repair the effects of radiation. So the probability of the risk of hereditary effects in generation II will be smaller.

References

Adnyana. 2014. Uji Kesesuaian Lampu Kolimasi Dengan Berkas Radiasi Menggunakan Alat Quality Control. Denpasar:Universitas Udayana.

Akhadi, M., 2000, Dasar-Dasar Proteksi Radiasi, Rineka Cipta, Jakarta.

Alatas, Z. 2006. Efek Pewarisan Akibat Radiasi, 65-74. Buletin Alara. BATAN

BAPETEN, 2020. Surat Keputusan Kepala Bapeten nomor 4 tentang Keselamatan Radiasi pada Penggunaan Pesawat Sinar-X dalam Radiologi Diagnostik dan Intervensional. Jakarta

BATAN, 2013. Petugas Proteksi Radiasi Medik Tingkat 2 dan Ringkat 3. Pusat Pendidikandan Pelatihan Badan Tenaga Nuklir Nasional.

Beiser, A.2003.Concepts of Modern Physics.Sixht Edition. New York:MeGraw-Hill.

Boddy, M.S. 2013. “Pengaruh Radiasi Hambur Terhadap Kontras Radiografi Akibat Variasi Ketebalan Objek dan Luas Lapangan Penyinaran”. Sulsel

Darmini, J. D. 2014. Penerimaan Dosis Radiasi Pada Pemeriksaan Radiografi Konvensional kontras, 460-466.

Dowsett, D. J., Patrick A. Kenny dan Eugene Johnston. R .2006. The Physics of Diagnostic Imaging: Second Imaging. United Kingdom: Hodder Arnold, an imprint of Hodder Education.

Gustia, R.M. 2021. Analisis Sebaran Radiasi Hambur Pesawat Sinar-X Konvensional di Instalasi Radiologi RSIA Zainab. Karya Tulis Ilmiah. Pekanbaru: STIKES Awal Bros.

IAEA. 2007, Dosimetry in Diagnostic Radiology: An International Code of Practice, Technical Report Series No. 457, Vienna.

Jeong, Woo Kyung. 2011. Radiation exposure and its reduction in the fluoroscopic examination and fluoroscopy-guided interventional radiology.

Mayerni, Adrianto A., Zainal A. 2013. Dampak radiasi terhadap kesehatan pekerja radiasi di RSUD Arifin Ahmad, RS Santa Maria, dan RS Awal Bros Pekanbaru. Jurnal Ilmu Lingkungan. Program Studi Ilmu Lingkungan PPS Universitas Riau.

Noerwasana. 2010. Analisis Sebaran Hambur Dari Pasien Pada Pesawat Fluoroskopi Dengan Metode Monte Carlo Dan Pengukuran. Jakarta:Universitas Indonesia.

Nova, Rahman. 2009. Radiofotografi. Padang: Universitas Baiturrahman.

Rasad. 2005. Buku Radiologi Diagnostik, Edisi Kedua, Jakarta: Balai Penerbit FK UI.

Rusli, M. 2017. Uji Keselamatan Paparan Radiasi Sinar-X di Radiologi ATRO

Muhammadiyah Makassar. Skripsi. Konsentrasi Medik, Departemen Fisika, Fakultas Matematika dan Ilmu Pengetahuan Alam: Universitas Hasanuddin Makassar.

Sartinah, Sumariyah, Ayu. N, 2008. Variasi nilai eksposi aturan 15% pada radiografi di RSUD dr. Soetomo Surabaya. Skripsi. Surabaya: Universitas Airlangga Surabaya.

Suliman, I.I., 2020. Estimates of Patient Radiation Doses in Digital Radiography Using DICOM Information at a Large Teaching Hospital in Oman. J. Digit. Imaging 33, 64-70.

Susanto, E., Wibowo, A.S., Kartikasari, Y., Masrochah, S., Indrati, R., dan Darmini. 2011. Materi Diklat Petugas Proteksi Radiasi Bidang Radiodiagnostik. Semarang: Politeknik Kesehatan.

UNSCEAR 2001., Hereditary Effects of Radiation. Report to the General Assemblywith Scientific Annex. New York, United Nations.

Downloads

Published

2022-12-30

Issue

Section

Articles